Search results for "Tuned liquid column damper"
showing 10 items of 14 documents
Experimental validation of a direct pre-design formula for TLCD
2014
The passive control of vibrations has received in recent years a great deal of attention from researchers. Several types of devices have been proposed in order to reduce the dynamic responses of different kinds of structural systems. Among them, the Tuned Liquid Column Damper (TLCD) has proved to be very effective in reducing vibration of structures. However, since the equations governing the TLCD controlled systems response is nonlinear, the calibration of TLCD parameters is time consuming and not convenient to perform in a pre-design phase. In this context, it has recently been introduced by the authors a formula that allows to choose the optimal parameters of TLCD in a direct and fast wa…
Innovative modeling of tuned liquid column damper controlled structures
2016
In this paper a different formulation for the response of structural systems controlled by Tuned Liquid Column Damper (TLCD) devices is developed, based on the mathematical tool of fractional calculus. Although the increasing use of these devices for structural vibration control, it has been demonstrated that existing model may lead to inaccurate prediction of liquid motion, thus reflecting in a possible imprecise description of the structural response. For this reason the recently proposed fractional formulation introduced to model liquid displacements in TLCD devices, is here extended to deal with TLCD controlled structures under base excitations. As demonstrated through an extensive expe…
Combining TMD and TLCD: analytical and experimental studies
2017
Abstract In these years several research efforts have been focused on developing efficient and reliable control devices for mitigating the structural response of tall and lightly damped buildings in case of strong dynamic excitations, such as wind and earthquake ones. In this context, Tuned Mass Dampers (TMDs) represent probably the most common control device due to their high control performances. On the other hand, Tuned Liquid Column Dampers (TLCDs) are increasingly becoming more popular because of some of their attractive features, cost-effectiveness among the others, even though they yield slightly less control performance compared to the classical TMDs. Aiming at combining the benefic…
The TLCD Passive Control: Numerical Investigations vs. Experimental Results
2012
Very recently the tuned liquid column damper (TLCD) is receiving an increasing interest from researchers concerned with vibration control, to be considered an alternative device with respect to the tuned mass damper (TMD), since the former has low cost, easy adjustment, flexible installation. However, in recent studies the authors [1] have pointed out that for TMD the analytical formulation provides results that are in good agreement with the experimental ones, while for TLCD it has been deducted that the analytical formulation needs further investigation. In fact using the classical formulation of the problem, numerical results are very different from the experimental results obtained by t…
Base-isolated structure equipped with tuned liquid column damper: An experimental study
2019
Abstract In this study, a novel passive vibration control strategy is investigated experimentally, where a Tuned Liquid Column Damper protects a base-isolated structure. The Tuned Liquid Column Damper is attached to the base, in contrast to typical attachment points of passive energy dissipation devices in high-rise buildings at elevated levels. Experiments on a base-excited small-scale three-story shear frame are conducted in order to study effects of both control devices – base-isolation and Tuned Liquid Column Damper – on the structural model. The dynamic properties of the stand-alone shear frame and the base-isolation subsystem are derived using standard dynamic test methods based on di…
Optimal design of tuned liquid column damper inerter for vibration control
2022
Abstract In this paper, the use of a novel passive control device defined as Tuned Liquid Column Damper Inerter (TLCDI) is studied to control the seismic response of structural systems. The TLCDI, recently introduced as an enhanced version of the conventional Tuned Liquid Column Damper, may achieve improved seismic performances by exploiting the mass amplification effect of the so-called inerter device. For this purpose, an optimization procedure for the design of the TLCDI based on a statistical linearization technique and the minimization of the structural displacement variance is proposed. Notably, by assuming a white noise base excitation and considering some additional approximations, …
Optimal design of tuned liquid column dampers for seismic response control of base-isolated structures
2017
In this paper, the use of a tuned liquid column damper (TLCD) as a cost-effective means to control the seismic response of a base-isolated structure is studied. A straightforward direct approach for the optimal design of such a device is proposed, considering a white noise model of the base excitation. On this base, a direct optimization procedure of the TLCD design parameters is performed and optimal design charts are presented as a ready-to-use practical design tool. Comparison with the optimal parameters obtained considering a classical iterative statistical linearization technique proves the reliability of the proposed approach. The performance of the base-isolated TLCD-controlled struc…
Optimal tuning of tuned liquid column damper systems in random vibration by means of an approximate formulation
2014
Passive control devices are often added to slender and flexible systems in order to increase their structural safety. Several types of devices have been proposed in order to reduce the dynamic responses of different kind of structural systems. Among them, the tuned liquid column damper (TLCD) proved to be very effective in reducing vibration of various type of structures by means of a combined action which involves the motion of the liquid mass within the tube. The restoring force, in particular, is produced by the force of gravity acting on the liquid and the damping effect is generated by the hydrodynamic head losses that arise during the motion of the liquid inside the TLCD. Since the in…
Direct evaluation of the equivalent linear damping for Tuned Liquid Column Damper systems in random vibration for pre-design purposes
2014
Innovative modeling of Tuned Liquid Column Damper motion
2015
Abstract In this paper a new model for the liquid motion within a Tuned Liquid Column Damper (TLCD) device is developed, based on the mathematical tool of fractional calculus. Although the increasing use of these devices for structural vibration control, it is shown that existing model does not always lead to accurate prediction of the liquid motion. A better model is then needed for accurate simulation of the behavior of TLCD systems. As regards, it has been demonstrated how correctly including the first linear liquid sloshing mode, through the equivalent mechanical analogy well established in literature, produces numerical results that highly match the corresponding experimental ones. Sin…